1. Technical specifications; I. Size of the Incinerator 4,410W x 3,037L x 4,836H mm II. Capacity […]
a burner which can melting in between 3 to 5 tonnes per day of mixed waste […]
Basic Info. Model NO.:A4000 Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:CLOVER Product […]
Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:clover Product Description Key […]
Zero-emission Solid Waste Incinerators for Eco-friendly Disposal: Pioneering the Future of Waste Management In an era […]
High-Volume Incinerators for High-Density Waste Areas: Efficient Solutions for Waste Management Introduction In high-density waste areas, […]
SMART ASH INCINERATORS FOR THE DISPOSAL OF HAZARDOUS WASTE ? Amount: 20 units ? The Burner […]
Product Description Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. […]
Medical Waste Incinerator, 50 to 60 Kg/hrSupport Health Sector Support ProjectPoint of Installation (Hospitals) Moi Voi, Makindu, Maragua, Eldama Ravine and Isiolo District Hospitals1.    General DescriptionSupply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal of Medical, General and Pathological waste in a safe and clean environment.  The unit shall consist of two chambers and operate on the principal of controlled air and temperature. The unit shall consist a particulate remover (scrubbers) as stipulated in waste management regulations, 2006 (Legal notice NO. 121 of 29th September, 2006).  The Unit shall be fully automatic and controlled by an automatic electronic controlled system except loading system which shall be manual.  The unit shall be capable of incinerating between 50 to 60 kg of solid medical waste per hour.  It shall be constructed from mild or aluminized steel lined with refractory material.Main unit Application For incineration, general and pathologicalCapacity   50 C 60 kg/h burn rateType Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unitOperating time                Minimum 8 hours dailyOperating temperature     From 850 0C to 1200 0C, Automatic controlledResidual Ash                    5 to 10%    3.2     Primary ChamberConstruction Constructed from heavy duty mild or aluminized  steel Orequal and approved equivalentInsulation material            Refractory material lining similar or equal to calcium Silicate and hot face combination of heavy duty brickworkInternal Construction        Fixed hearth type complete with gratings, concave bottomand charging door, lined with refractory materialCharging Door                   Suitable for manual loading of wastes and with smooth Dear seal equivalent of Ceramic seals with hinges.Door Lock                          Automatic, Electric typeAsh removal door    Provided, for removing resultant bottom ash leftovers                              from the Primary chamberGratings   […]
Q: what is kind of waste can use in this equipment?A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any  explosive and radiation material, liquid waste and gas waste. Q: Incinerator Smoke StandardA: China Government Standard: No.GB18484-2001. Q: Treatment capacityA: Average Capacity calculated by medical waste(lower calorific power (L.C.P): 3.0TH Kcal/Kg per hour),  not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity.   Clover incinerator use time per day up to 24 hours. Between each feed/combustion time,  there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion  time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use.  Generally, we proposal small laboratory, small clinic use capacity under 20 kgs per hour.  When incinerator use in hospital, please calculate the waste output capacity around 2kgs  per people per day. If there are 200 sickbed in the hospital, that’s mean you need one  incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs  per hour. According the operation time per day, waste material, budget,  development, etc, you can use capacity from 30-50 kgs per hour incinerator.*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. Q: Assembly and TestingA: We supply all documents and incinerators easy to installation and operation. Customer  can send people come to our factory to learn installation and operation. Generally,  […]
Q: what is kind of waste can use in this equipment? A: This equipment for medical […]
Medical Incinerator: Advanced Solutions for Medical Waste Management In today’s increasingly complex healthcare environment, efficient and […]
Industrial-Grade Medical Waste Incinerators for Hospitals Introduction to Industrial-Grade Medical Waste Incineration Medical waste is one […]
chemical agents to be utilized: 10% heptyl (unsymmetrical dimethylhydrazine) water solution, heptyl (unsymmetrical dimethylhydrazine) vapour with […]
About

HICLOVER Solution for Fighting COVID-19, with ISO9001:2015/CE(2006/42/EC,2014/30/EU) Certification.Medical Waste Incinerator |Mobile Incinerator|
Pet Animal Incinerator|Municipal Solid Waste Incinerator

Waste Incinerators