General specifications of a 100 kg/hr incinerator No. Description Parameter value model HICLOVER […]
Basic Info. Model NO.:cost of an incinerator with 20kg/hr loading rate Pullution Sources:Solid Waste Processing Processing […]
Waste is thermally decomposed in the primary chamber at temperatures of 800 °C +. The resulting […]
1. SCOPE OF FUNCTION The work specified in the contract will certainly include. 1. Supply, mount […]
medical waste incinerator china, Design, supply and manufacture ex works of one Surefire Manual Load TS50/1 […]
HICLOVER now supplies extra parts consisting of: — — Burners (diesel oil, LPG or natural gas) […]
medical waste incinerator: medical waste and general waste Capacity to burn waste: 400 — 500 kg/hr […]
Product Description Technology Respond(FAQ) Q: What is kind of waste can use in this equipment? A: […]
a. 2.5 metric tons per day healthcare waste incinerator b. 1.5 metric tons per day healthcare […]
Capacity Not less than 500Kg/hr.Operation 24hr-7days/week continuous operation.Combustion chamber 2 combustion chamber.Temp. First combustion chamber 800-1000 C. Secandry combustion chamber 1000-1200 C, with the possibility to be upgraded to 1400 C.Combustion Efficiency 99.99%Retention time Of the flow gases not less than 2 Sec in the hot portion.Excess Oxygen concentration Of primary combustion chamber 3-6% max. Refractory The chambers should be lined with high thermal insulating refractory bricks with suitable thickness and with highly temp. resistance. Not less than 1400 C for the first combustion chamber, and not less than 1600 C for the secandry combustion chamber, and at the same time prevent the Temp. of the outside body of the chamber not higher than 70 C.Doors Should be lined with the same bricks, and the edges lined with special suitable insulating material to prevent any gas escaping, and the doors should be kept under negative pressure during the operation.Air Emission Control System With high destruction and removal efficiency (DRE). Not less than 99.9999 as per KEPA.Wet System If the system equiped with a CEMS washing the flow gas with water, then it should be manufactured from suitable anti corrossion materials, and equiped with pH meter to measure and neutralize the water. It should be able to use the water in closed recycled circuit many times before treating/ discharging into the sewage system in compliance with KEPARS.Chemical dosing It should be equiped with suitable autochemical dosing system to control the pH for the water of the wet scrubber system including sensors.Chimney It should be suitable with the capacity and the technical specifications, with height not less than 12m from ground level. With easy opennable sampling point equal about 3 inch, and the optimum sampling locations is at least 8D downstream direction and 2D upstream from any flow disturbancies.Sampling point […]
HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet […]
Automatic Incinerators for Reducing Manual Labor in Waste Disposal In modern waste management, efficiency and environmental […]
Waste Heater Design TS150 PLC, Review This design is small-scale waste incineration tools for tiny waste […]
Product Description Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. […]
Affordable Pet Cremation Incinerators for Animal Services: A Comprehensive Guide When it comes to providing dignified, […]