small scale incinerator

? Refractory concrete :
OA burner of lighting which the use is restricted to the ignition of waste.
OA sheath of evacuation of the gases burnt.
? Refractory concrete :
OA apparatus of air ducts of cooling of waste gases,
OThe insulation of the combustion chamber ought to be composed of refractory bricks, using a high content of aluminum and insulates bricks in order to guarantee a minimum temperature on the exterior sheet metal.
OCarcass in solid sheet steel with support of link.
? Nature: 65 percent of Al203
Plate of combustion in Carborundum, preventing the fixing of glass and slags

A room of post combustion of gases
Control box watertight to dust, such as:

A switch circuit breaker for each engine (ventilators and burners).
OElectro-ventilator distributing the secondary atmosphere, the regulation of the air flow being carried out by valves and adhering to the control of the automatic cycle.
? Nature: Calcium
. Thickness    : ≥100 mm
? Thickness: ≥85 mm
OBurner with fuel, mono-bloc casting directing type with horizontal flame, lighting and security of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
OFrontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.
? Insulate in fibrous panel :
A timer with adjustable temporization for the regulation of every burner.
? Burner of lighting of waste, with gas, regular mono-bloc casting guiding  plunging flame, lighting and security of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
OA secondary injection of air to ensure perfect oxygen content.

A control box ensuring that the complete cycle of combustion.

Fan:
A regulator with digital viewing for the temperature of combustion.
OA apparatus of injection of air allowing a total recombustion of gases,
. Nature: 42% of Al203
Nature: Calcium silicate.
Fuel? : diesel

Manufacturer to provide  necessary information for the best of  the setup

The control panel shall have all suitable audible and visual alerts to ensure safe performance.

This incinerator with”PYROLYTIC” combustion should possess:
? Insulate in fibrous panels :
?
OComposition of the refractory;
Thickness: ≥75 mm

Incinerators Biological waste disposal system (incinerator)

Incinerator must meet these specifications:

—       Combustion capacity (kW) = 581 +/-10%

—       Combustion capacity (kcal/h) = 500,000 +/-10%

—       Max. l/h (at approx. . 50% water content) = 100 +/-10%

Further specifications will be supplied with the inquiry.

The incinerator shall be fully self contained.

The incinerator plant shall incorporate a control panel for its own operation. On the control panel we shall have a visual display of the room temperatures. This visual display must control and monitor the incinerator and his performance.

Capacity of destruction in weight shall be 60 Kg/h.

it ought to be able to operate not less than 10 hours/day

This incinerator has to have the ability to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…

Design Specification: Types A, B, C, D, and E of medical waste

“PYROLYTIC” combustion, by controlling the gasification of waste.

The incinerator should prevent the discharge of black smoke and dust that is fine, during the loadings.

It shall have the ability to reduce the volume of wastes by 98%.

It shall have the ability to hold emission in the second burn with gas residence of not less than 2 seconds.

The incineration should be wholly free from visible smoke in addition to offensive odours.

1.0The primary ignition burner shall providing ignition of the waste to 850 °C and has to switch off to conserve fuel.

the principal combustion chamber shall be constructed from heavy steel plate and the unit is internally lined with a complete layer of hote face refractory and high efficiency insulation.

The Internal diameter of the Chimney at least: ? 400 and its elevation: 8 m

The Volume of the combustion chamber at least: 1.200 L

The Dimension of the door for loading in cm : 70×70.

Burner operation should be Automatic On/Off
1. A combustion chamber of waste:
Electric box

The secondary combustion chamber must destroy the contaminant product and must resist high temperatures (1100 °C)

Process Filtering system: Scruber to be mentionned as discretionary